Product Features
Precise outlet pressure control with high pressure regulation accuracy; fast response and excellent shut-off performance.
Simple pressure setting, easy installation and maintenance; compact structure allowing online maintenance and requiring minimal installation space.
Integrated pressure regulation and overpressure shut-off available.
Applicable Media
Natural gas, manufactured gas, liquefied petroleum gas, air and other non-corrosive gases.
Suitable for small gas-fired boilers and industrial furnaces; can serve as a load regulator for large regulators.
Technical Parameters
Inlet pressure P₁: 0.2–4.0 MPa
Outlet pressure P₂: 0.1–0.4 MPa
Pressure regulation accuracy class: AC10
Shut-off accuracy: 1%
Lock-up pressure class: SG20
Operating temperature: -20°C ~ 60°C
Nominal pressure: PN16, PN25, PN40
Nominal diameter: DN25, DN40, DN50
RTZ1-5( /1.6-GQ (Ductile Iron) Flow Rate Table (MPa)
| P₁ \ P₂ | 0.1 | 0.15 | 0.2 | 0.25 | 0.3 | 0.35 | 0.4 |
|---|---|---|---|---|---|---|---|
| 0.2 | 155 | 130 | — | — | — | — | — |
| 0.3 | 210 | 205 | 190 | 155 | — | — | — |
| 0.4 | 260 | 260 | 260 | 250 | 225 | 175 | — |
| 0.5 | 310 | 310 | 310 | 310 | 305 | 290 | 255 |
| 0.6 | 365 | 365 | 365 | 365 | 365 | 360 | 345 |
| 0.7 | 415 | 415 | 415 | 415 | 415 | 415 | 410 |
| 0.8 | 470 | 470 | 470 | 470 | 470 | 470 | 470 |
| 1.0 | 570 | 570 | 570 | 570 | 570 | 570 | 570 |
| 1.2 | 675 | 675 | 675 | 675 | 675 | 675 | 675 |
| 1.6 | 885 | 885 | 885 | 885 | 885 | 885 | 885 |
Note: The flow values in the table are measured under standard conditions for natural gas with a relative density of 0.6.
RTZ1-50/4.0-GQ (Forged Steel Body) Flow Rate Table (MPa)
| P₁ \ P₂ | 0.1 | 0.15 | 0.2 | 0.25 | 0.3 | 0.35 | 0.4 |
|---|---|---|---|---|---|---|---|
| 1.0 | 525 | 525 | 525 | 525 | 525 | 525 | 525 |
| 1.2 | 620 | 620 | 620 | 620 | 620 | 620 | 620 |
| 1.5 | 765 | 765 | 765 | 765 | 765 | 765 | 765 |
| 1.8 | 910 | 910 | 910 | 910 | 910 | 910 | 910 |
| 2.0 | 1005 | 1005 | 1005 | 1005 | 1005 | 1005 | 1005 |
| 2.2 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 |
| 2.5 | 1245 | 1245 | 1245 | 1245 | 1245 | 1245 | 1245 |
| 2.8 | 1385 | 1385 | 1385 | 1385 | 1385 | 1385 | 1385 |
| 3.0 | 1480 | 1480 | 1480 | 1480 | 1480 | 1480 | 1480 |
| 3.2 | 1580 | 1580 | 1580 | 1580 | 1580 | 1580 | 1580 |
| 3.5 | 1720 | 1720 | 1720 | 1720 | 1720 | 1720 | 1720 |
| 3.8 | 1865 | 1865 | 1865 | 1865 | 1865 | 1865 | 1865 |
| 4.0 | 1960 | 1960 | 1960 | 1960 | 1960 | 1960 | 1960 |
Note: The flow values in the table are measured under standard conditions for natural gas with a relative density of 0.6.
RTZ1-25/4.0-GQ (Forged Steel Body) Flow Rate Table (MPa)
| P₁ \ P₂ | 0.1 | 0.15 | 0.2 | 0.25 | 0.3 | 0.35 | 0.4 |
|---|---|---|---|---|---|---|---|
| 0.2 | 120 | 100 | — | — | — | — | — |
| 0.3 | 160 | 160 | 150 | 120 | — | — | — |
| 0.4 | 200 | 200 | 200 | 195 | 175 | 135 | — |
| 0.5 | 245 | 245 | 245 | 245 | 240 | 225 | 200 |
| 0.6 | 285 | 285 | 285 | 285 | 285 | 280 | 270 |
| 0.7 | 325 | 325 | 325 | 325 | 325 | 325 | 325 |
| 0.8 | 365 | 365 | 365 | 365 | 365 | 365 | 365 |
| 1.0 | 445 | 445 | 445 | 445 | 445 | 445 | 445 |
| 1.2 | 530 | 530 | 530 | 530 | 530 | 530 | 530 |
| 1.5 | 650 | 650 | 650 | 650 | 650 | 650 | 650 |
| 1.8 | 775 | 775 | 775 | 775 | 775 | 775 | 775 |
| 2.0 | 855 | 855 | 855 | 855 | 855 | 855 | 855 |
| 2.2 | 935 | 935 | 935 | 935 | 935 | 935 | 935 |
| 2.5 | 1060 | 1060 | 1060 | 1060 | 1060 | 1060 | 1060 |
| 2.8 | 1180 | 1180 | 1180 | 1180 | 1180 | 1180 | 1180 |
| 3.0 | 1265 | 1265 | 1265 | 1265 | 1265 | 1265 | 1265 |
| 3.2 | 1345 | 1345 | 1345 | 1345 | 1345 | 1345 | 1345 |
| 3.5 | 1470 | 1470 | 1470 | 1470 | 1470 | 1470 | 1470 |
| 3.8 | 1590 | 1590 | 1590 | 1590 | 1590 | 1590 | 1590 |
| 4.0 | 1670 | 1670 | 1670 | 1670 | 1670 | 1670 | 1670 |
Note: The flow values in the table are measured under standard conditions for natural gas with a relative density of 0.6.